Sorry, you need to enable JavaScript to visit this website.
Skip to main content
Study

Performance of a fail-safe system to follow up abnormal mammograms in primary care.

Grossman E, Phillips RS, Weingart SN. Performance of a fail-safe system to follow up abnormal mammograms in primary care. J Patient Saf. 2010;6(3):172-179.

Save
Print
September 8, 2010
Grossman E, Phillips RS, Weingart SN. J Patient Saf. 2010;6(3):172-179.
View more articles from the same authors.

Tests pending after hospital discharge or following a clinic visit continue to challenge most health care systems. This study implemented a paper-based system to follow up abnormal mammograms and monitored provider responses to those reminders. Based on a report of abnormal mammograms generated by the radiology department, a practice administrator sent a letter to each provider with a copy of the report and a set of questions on behalf of their quality improvement committee. More than 90% of providers responded to the fail-safe reminders, 8% were unaware of the abnormal test, and there was no follow-up plan in place for 3% of cases. Less experienced providers were more likely to be unaware of abnormal mammograms and many lapses were noted in the context of care transitions. The authors conclude that their paper-based system is feasible and valuable but requires full engagement of providers in the process.

Save
Print
Cite
Citation

Grossman E, Phillips RS, Weingart SN. Performance of a fail-safe system to follow up abnormal mammograms in primary care. J Patient Saf. 2010;6(3):172-179.

Related Resources From the Same Author(s)
Related Resources