Multimodal system designed to reduce errors in recording and administration of drugs in anaesthesia: prospective randomised clinical evaluation.
Merry AF, Webster CS, Hannam J, et al. BMJ. 2011;343:d5543.

Drug administration errors are a major safety concern in anesthesiology, as even routine cases can require administration of several high-risk medications. In this randomized controlled trial, a novel system for drug administration was evaluated in comparison with usual anesthesia practice. The new system was designed according to human factors engineering principles and included proven safety measures such as barcode medication administration. Although fewer overall errors occurred with the new system, the reduction in administration errors occurred only when barcoding was performed consistently and safety alerts were heeded. The anesthesia field has long been a leader in patient safety, and in fact, some of the earliest studies in the patient safety field evaluated the role of human factors in anesthesia medication administration errors.

PubMed citation icon indicating hyperlink to external website
Available at icon indicating hyperlink to external website
Related editorial icon indicating hyperlink to external website
white box
Related Resources
NEWSPAPER/MAGAZINE ARTICLE
Medication errors occurring with the use of bar-code administration technology.
PA-PSRS Patient Saf Advis. December 2008;5:122-126.
COMMENTARY
Vial Mistakes Involving Heparin.
Vanderveen T. AHRQ WebM&M [serial online]. May 2009.
REVIEW
Medication errors—new approaches to prevention.
Merry AF, Anderson BJ. Paediatr Anaesth. 2011;21:743-753.
View all related resources...