Skip Navigation
The Collection >
The impact of a closed-loop electronic prescribing and administration system on prescribing errors, administration errors and staff time: a before-and-after study.
Franklin BD, O'Grady K, Donyai P, Jacklin A, Barber N. Qual Saf Health Care. 2007;16:279-284.

Measures that have been proposed to reduce the incidence of medication errors target prescribing safety (e.g., computerized provider order entry) or safety in administering medications (e.g., bar coding or automated dispensing). While each of these individual measures has been shown to decrease errors, as yet few systems "close the loop" by integrating safety measures for prescribing and administering medications. Utilizing an electronic system that incorporated CPOE, automated dispensing, bar coding, and an electronic medication record, this single-institution study demonstrated a significant reduction in both prescribing errors and administration errors. However, staff time spent on medication-related tasks increased. While the study results are promising, one caveat is that the system was not used for high-risk drugs such as anticoagulants or intravenous medications.

PubMed citation icon indicating hyperlink to external website
Available at icon indicating hyperlink to external website
Free full text icon indicating hyperlink to external website
white box
Related Resources
STUDY
Effect of bar-code technology on the safety of medication administration.
Poon EG, Keohane CA, Yoon CS, et al. N Engl J Med. 2010;362:1698-1707.
STUDY
Methodological variability in detecting prescribing errors and consequences for the evaluation of interventions.
Franklin BD, Birch S, Savage I, et al. Pharmacoepidemiol Drug Saf. 2009;18:992-999.
COMMENTARY
In Conversation with…Eric G. Poon, MD, MPH
AHRQ WebM&M [serial online]. September 2008.
View all related resources...