@article{14761, author = {Sonam N Shah and Mary G. Amato and Katherine G Garlo and Diane L. Seger and David W. Bates}, title = {Renal medication-related clinical decision support (CDS) alerts and overrides in the inpatient setting following implementation of a commercial electronic health record: implications for designing more effective alerts}, abstract = {Abstract Objective To assess the appropriateness of medication-related clinical decision support (CDS) alerts associated with renal insufficiency and the potential/actual harm from overriding the alerts. Materials and Methods Override rate frequency was recorded for all inpatients who had a renal CDS alert trigger between 05/2017 and 04/2018. Two random samples of 300 for each of 2 types of medication-related CDS alerts associated with renal insufficiency—“dose change” and “avoid medication”—were evaluated by 2 independent reviewers using predetermined criteria for appropriateness of alert trigger, appropriateness of override, and patient harm. Results We identified 37 100 “dose change” and 5095 “avoid medication” alerts in the population evaluated, and 100% of each were overridden. Dose change triggers were classified as 12.5% appropriate and overrides of these alerts classified as 90.5% appropriate. Avoid medication triggers were classified as 29.6% appropriate and overrides 76.5% appropriate. We identified 5 adverse drug events, and, of these, 4 of the 5 were due to inappropriately overridden alerts. Conclusion Alerts were nearly always presented inappropriately and were all overridden during the 1-year period studied. Alert fatigue resulting from receiving too many poor-quality alerts may result in failure to recognize errors that could lead to patient harm. Although medication-related CDS alerts associated with renal insufficiency had previously been found to be the most clinically beneficial alerts in a legacy system, in this system they were ineffective. These findings underscore the need for improvements in alert design, implementation, and monitoring of alert performance to make alerts more patient-specific and clinically appropriate. }, year = {2021}, journal = {J Am Med Inform Assoc}, volume = {28}, pages = {1081-1087}, month = {09/2020}, issn = {1067-5027}, doi = {10.1093/jamia/ocaa222}, }