@article{5140, keywords = {Hospital, Patient safety, Patient satisfaction, Questionnaire}, author = {Oyvind Bjertnaes and Kjersti Eeg Skudal and Hilde Hestad Iversen and Anne Karin Lindahl}, title = {The Patient-Reported Incident in Hospital Instrument (PRIH-I): assessments of data quality, test-retest reliability and hospital-level reliability.}, abstract = {
BACKGROUND: The objective of this study was to test the data quality, test-retest reliability and hospital-level reliability of the Patient-Reported Incident in Hospital Instrument (PRIH-I).
METHODS: 13 incident questions were included in a national patient-experience survey in Norway during the spring of 2011. All questions and a composite incident index were assessed by calculating missing-item rates, test-retest reliability and hospital-level reliability. A multivariate linear regression on a global item regarding incorrect treatment was used to assess the main sources of variation in patient-perceived incorrect treatment at hospitals.
RESULTS: Five of the 13 patient-incident questions had a missing-item rate of >20%. Only one item met the criterion of 0.7 for test-retest reliability (wrong or delayed diagnosis), seven items had a score of >0.5, while the remainder had a reliability score of <0.5. However, the reliability was >0.7 for six of 10 items tested at the hospital level, and >0.6 for the remaining four items. A patient-incident index based on 12 of the incident items had no missing data, the test-retest reliability was 0.6 and the hospital-level reliability was 0.85.
CONCLUSIONS: The PRIH-I comprises 13 questions about patient-perceived incidents in hospitals, and can be easily and cost-effectively included in national patient-experience surveys with an acceptable increase in respondent burden. Although the missing-item rate and test-retest reliability were poor for several items, the hospital-level reliability was satisfactory for most of the items. The incident items contribute to a patient-reported incident index, with excellent data quality and hospital-level reliability.
}, year = {2013}, journal = {BMJ Qual Saf}, volume = {22}, pages = {743-51}, month = {09/2013}, issn = {2044-5423}, doi = {10.1136/bmjqs-2012-001756}, language = {eng}, }