A powerful anti-clotting medication is ordered for a patient admitted for coronary intervention. Due to a forcing function in the computer order entry system, the intern enters an arbitrary maintenance infusion rate, assuming that the pharmacy will fix it if it is wrong. The pharmacy dispenses it as written, and the nurse administers it—underdosing the patient by a factor of 40.
A pregnant woman with asthma was admitted to the hospital with respiratory distress. Although the emergency department providers noted that she was pregnant, this information was not conveyed to the floor. On admission, the patient was given an antibiotic that could have been dangerous.