A 61-year-old women with a mechanical aortic valve on chronic warfarin therapy was referred to the emergency department (ED) for urgent computed tomography (CT) imaging of the right leg to rule out an arterial clot. CT imaging revealed two arterial thromboses the right lower extremity and an echocardiogram revealed a thrombus near the prosthetic heart valve. The attending physician ordered discontinuation of warfarin and initiation of a heparin drip.
This case describes a 20-year-old woman was diagnosed with a pulmonary embolism and occlusive thrombus in the right brachial vein surrounding a peripherally inserted central catheter (PICC) line (type, gauge, and length of time the PICC had been in place were not noted). The patient was discharged home but was not given any supplies for cleaning the PICC line, education regarding the signs of PICC line infection, or referral to home health services.