The PSNet Collection: All Content
Search All Content
A 55-year-old man presented in hypotensive shock, presumably due to bacterial pneumonia superimposed on COPD. The nurse placed an arterial line appropriately in the patient’s radial artery for hemodynamic monitoring, but this line was inadvertently used to infuse an antibiotic. The patient experienced acute arterial thrombosis with resulting hand ischemia but responded to rapid thrombolytic and anticoagulant therapy.
This case involves a procedural sedation error in a 3-year-old patient who presented to the Emergency Department with a left posterior hip dislocation. The commentary summarizes the indications and risks of procedural sedation in non-surgical settings and highlights the value of implementing system-wide safety protocols and practices to prevent medication administration errors during high-risk procedures.
Horsham, PA; Institute for Safe Medication Practices: April 2023.
Although wrong-site surgeries are rare, they can be devastating to patients. One otolaryngology (ENT) clinic developed a surgical marking procedure deemed practicable and useful by both providers and patients.
A 72-year-old man was diagnosed with COVID-19 pneumonia and ileus, and admitted to a specialized COVID care unit. A nasogastric tube (NGT) was placed, supplemental oxygen was provided, and oral feedings were withheld. Early in his hospital stay, the patient developed hyperactive delirium and pulled out his NGT. Haloperidol was ordered for use as needed (“prn”) and the nurse was asked to replace the NGT and confirm placement by X-ray. The bedside and charge nurses had difficulty placing the NGT and the X-ray confirmation was not done.
This piece discusses resilient healthcare and the Safety-I and Safety-II approaches to patient safety.
This piece discusses resilient healthcare and the Safety-I and Safety-II approaches to patient safety.

Ellen Deutsch, MD, MS, FACS, FAAP, FSSH, CPPS is a Medical Officer in the Center for Quality Improvement and Patient Safety at the Agency for Healthcare Research and Quality. Dr. Deutsch is a pediatric otolaryngologist and has vast experience in simulation and resilience engineering. We spoke with her about resilient healthcare and how resilient engineering principles are applied to improve patient safety.
This WebM&M describes two cases involving patients who became unresponsive in unconventional locations – inside of a computed tomography (CT) scanner and at an outpatient transplant clinic – and strategies to ensure that all healthcare teams are prepared to deliver advanced cardiac life support (ACLS), such as the use of mock codes and standardized ACLS algorithms.
Jagsi R, Griffith KA, Vicini F, et al for the Michigan Radiation Oncology Quality Consortium. JAMA Oncol. Epub 2022 Apr 21.
A 69-year-old man with End-Stage Kidney Disease (ESKD) secondary to diabetes mellitus and hypertension, who had been on dialysis since 2014, underwent deceased donor kidney transplant. The case demonstrates the complex nature of management of allograft dysfunction due to vascular complications in a patient with deceased donor kidney transplant in the early post-transplant period.
RA-UK, the Faculty of Pain Medicine, RCoA Simulation and NHS Improvement
This commentary presents two cases highlighting common medication errors in retail pharmacy settings and discusses the importance of mandatory counseling for new medications, use of standardized error reporting processes, and the role of clinical decision support systems (CDSS) in medical decision-making and ensuring medication safety.
Farnborough, UK: Healthcare Safety Investigation Branch; June 2021.