Sorry, you need to enable JavaScript to visit this website.
Skip to main content
Study

Prevalence of medication administration errors in two medical units with automated prescription and dispensing.

Rodriguez-Gonzalez CG, Herranz-Alonso A, Martin-Barbero ML, et al. Prevalence of medication administration errors in two medical units with automated prescription and dispensing. J Am Med Inform Assoc. 2012;19(1):72-8. doi:10.1136/amiajnl-2011-000332.

Save
Print
September 28, 2011
Rodriguez-Gonzalez CG, Herranz-Alonso A, Martin-Barbero ML, et al. J Am Med Inform Assoc. 2012;19(1):72-8.
View more articles from the same authors.

Technological solutions such as computerized provider order entry (CPOE) hold promise for reducing medication errors at the prescribing and dispensing stage, but patients may still be harmed by incorrect administration of medications, which have been shown to be disturbingly common in prior studies. Conducted at an academic hospital in Spain that had an established CPOE system, this study found an overall administration error rate of 22%, consistent with prior studies. The hospital in question did not have a barcoding medication administration system. Combining barcoding with CPOE in a closed-loop system has been shown to significantly reduce the overall medication error rate.

Save
Print
Cite
Citation

Rodriguez-Gonzalez CG, Herranz-Alonso A, Martin-Barbero ML, et al. Prevalence of medication administration errors in two medical units with automated prescription and dispensing. J Am Med Inform Assoc. 2012;19(1):72-8. doi:10.1136/amiajnl-2011-000332.

Related Resources From the Same Author(s)
Related Resources