A comparison of medication administration errors from original medication packaging and multi-compartment compliance aids in care homes: a prospective observational study.

Gilmartin-Thomas JF-M, Smith F, Wolfe R, et al. A comparison of medication administration errors from original medication packaging and multi-compartment compliance aids in care homes: A prospective observational study. Int J Nurs Stud. 2017;72:15-23. doi:10.1016/j.ijnurstu.2017.03.008.

Save
Print
June 21, 2017
Gilmartin-Thomas JF-M, Smith F, Wolfe R, et al. Int J Nurs Stud. 2017;72:15-23.
View more articles from the same authors.

This prospective, direct-observation study examined medication administration accuracy of medications dispensed by nurses and caregivers in long-term care facilities. Investigators compared medication administration from original medication packaging to administration from multicompartment medication devices. The team observed nearly 2500 doses. When medications were dispensed from original packaging, the medication administration error rate was 9%. When multicompartment devices were used, the medication administration error rate was 3%. This difference persisted in settings where both original packaging and multicompartment medication devices were used. This study adds to the evidence about how literacy-friendly health systems can enhance medication safety.

Save
Print
Cite
Citation

Gilmartin-Thomas JF-M, Smith F, Wolfe R, et al. A comparison of medication administration errors from original medication packaging and multi-compartment compliance aids in care homes: A prospective observational study. Int J Nurs Stud. 2017;72:15-23. doi:10.1016/j.ijnurstu.2017.03.008.

Related Resources From the Same Author(s)
Related Resources