Skip to main content

WebM&M: Case Studies

WebM&M (Morbidity & Mortality Rounds on the Web) features expert analysis of medical errors reported anonymously by our readers. Spotlight Cases include interactive learning modules available for CME. Commentaries are written by patient safety experts and published monthly.

Have you encountered medical errors or patient safety issues? Submit your case below to help the medical community and to prevent similar errors in the future.

This Month's WebM&Ms

Update Date: October 31, 2023
Have you encountered medical errors or patient safety issues?
Have you encountered medical errors or patient safety issues? Submit your case below to help the medical community and to prevent similar errors in the future.

All WebM&M: Case Studies (6)

Displaying 1 - 6 of 6 Results

A 48-year-old obese man with a history of obstructive sleep apnea was placed under general anesthesia for corneal surgery. On completion of the operation, the patient was transferred to a motorized gurney to extubate him in a sitting position because the operating room (OR) table was too narrow. However, while the team was moving him from the OR table to the gurney, a nurse inadvertently pulled on the anesthetic machine hoses. The endotracheal tube became dislodged and the patient could not be ventilated. The commentary discusses considerations for regional versus general anesthesia and appropriate steps for extubation in obese and other high-risk patients, including the use of high flow nasal oxygen.

Carla S. Martin, MSN, RN, CIC, CNL, NEA-BC, FACHE, Shannon K. Reese, BSN, RN, VABC, and Margaret Brown-McManus, MSN, RN, CNL | September 28, 2022

This case describes a 20-year-old woman was diagnosed with a pulmonary embolism and occlusive thrombus in the right brachial vein surrounding a  peripherally inserted central catheter (PICC) line (type, gauge, and length of time the PICC had been in place were not noted). The patient was discharged home but was not given any supplies for cleaning the PICC line, education regarding the signs of PICC line infection, or referral to home health services. During follow-up several days after discharge, the patient’s primary care provider noted that the PICC dressing was due to be changed and needed to be flushed, but the outpatient setting lacked the necessary supplies. An urgent referral to home health was placed, but the agency would be unable to attend to the patient for several days. The primary care provider changed the dressing, and the patient was referred to the emergency department for assessment. The commentary summarizes the risks of PICC lines, the role of infection prevention practices during the insertion and care of PICC lines, and the importance of patient education and skill assessment prior to discharge home with a PICC line.

Karen Ousey, PhD, RGN| February 1, 2014
A patient admitted for acute liver failure, acute renal failure, respiratory failure, and hepatic encephalopathy had a rectal tube placed to manage diarrhea. Two weeks into his hospitalization, dark red liquid stool was noted in the rectal tube, and the patient was found to have a large ulcerated area in the rectum, likely caused by the tube.
Philip Darney, MD, MSc| April 1, 2006
A woman has an intrauterine contraceptive device placed at the time of "her period." A month later it is discovered that she is pregnant, as she had been at the time of the insertion.
Jeremy P. Feldman, MD; Michael K. Gould, MD, MS | March 1, 2004
A central line placed incorrectly causes a patient to suffer permanent neurologic damage.
John Gosbee, MD, MS; Laura Lin Gosbee, MASc| February 1, 2003
An infusion pump being used for routine sedation in a child undergoing a magnetic resonance imaging (MRI) scan flew across the room and hit the MRI magnet, narrowly missing the child.