Skip to main content

WebM&M: Case Studies

WebM&M (Morbidity & Mortality Rounds on the Web) features expert analysis of medical errors reported anonymously by our readers. Spotlight Cases include interactive learning modules available for CME. Commentaries are written by patient safety experts and published monthly.

Have you encountered medical errors or patient safety issues? Submit your case below to help the medical community and to prevent similar errors in the future.

This Month's WebM&Ms

Update Date: November 16, 2022
Nasim Hedayati, MD, and Richard White, MD | November 16, 2022

A 61-year-old women with a mechanical aortic valve on chronic warfarin therapy was referred to the emergency department (ED) for urgent computed tomography (CT) imaging of the right leg to rule out an arterial clot. CT imaging revealed two... Read More

Leilani Schweitzer | November 16, 2022

A 58-year-old man underwent a complex surgery to replace his aortic valve. The surgery required prolonged cardiopulmonary bypass time and cross-clamp time and there was a short delay in redosing the cardioplegic solution and the patient developed ... Read More

Have you encountered medical errors or patient safety issues?
Have you encountered medical errors or patient safety issues? Submit your case below to help the medical community and to prevent similar errors in the future.

All WebM&M: Case Studies (2)

Displaying 1 - 2 of 2 WebM&M Case Studies
Carla S. Martin, MSN, RN, CIC, CNL, NEA-BC, FACHE, Shannon K. Reese, BSN, RN, VABC, and Margaret Brown-McManus, MSN, RN, CNL | September 28, 2022

This case describes a 20-year-old woman was diagnosed with a pulmonary embolism and occlusive thrombus in the right brachial vein surrounding a  peripherally inserted central catheter (PICC) line (type, gauge, and length of time the PICC had been in place were not noted). The patient was discharged home but was not given any supplies for cleaning the PICC line, education regarding the signs of PICC line infection, or referral to home health services. During follow-up several days after discharge, the patient’s primary care provider noted that the PICC dressing was due to be changed and needed to be flushed, but the outpatient setting lacked the necessary supplies. An urgent referral to home health was placed, but the agency would be unable to attend to the patient for several days. The primary care provider changed the dressing, and the patient was referred to the emergency department for assessment. The commentary summarizes the risks of PICC lines, the role of infection prevention practices during the insertion and care of PICC lines, and the importance of patient education and skill assessment prior to discharge home with a PICC line.

Jean L. Holley, MD | October 1, 2010
A man with end-stage renal disease on hemodialysis was dialyzed with equipment that had been inappropriately reused, exposing the patient to another patient's blood numerous times.