Update Date: May 16, 2022
Garima Agrawal, MD, MPH, and Mithu Molla, MD, MBA | May 16, 2022

This WebM&M describes two cases involving patients who became unresponsive in unconventional locations – inside of a computed tomography (CT) scanner and at an outpatient transplant clinic – and strategies to ensure that all healthcare teams are... Read More

Alexandria DePew, MSN, RN, James Rice, & Julie Chou, BSN | May 16, 2022

This WebM&M describes two incidences of the incorrect patient being transported from the Emergency Department (ED) to other parts of the hospital for tests or procedures. In one case, the wrong patient was identified before undergoing an... Read More

Have you encountered medical errors or patient safety issues?
Have you encountered medical errors or patient safety issues? Submit your case below to help the medical community and to prevent similar errors in the future.

All WebM&M: Case Studies (9)

1 - 9 of 9 WebM&M Case Studies
Deborah Debono, PhD, RN, and Tracy Levett-Jones, PhD, RN| July 1, 2018
A young adult with a progressive neurological disorder presented to an emergency department from a nursing home with a dislodged GJ tube. As a workaround to maintain patency when the GJ tube was dislodged, nursing home staff had inserted a Foley catheter into the ostomy, inflated the Foley bulb in the stomach, and tied the distal portion of the catheter in a loose knot. When the patient went to interventional radiology for new GJ tube placement, clinicians found no Foley but inserted a new GJ tube. Discharged to the nursing home, the patient was readmitted 2 days later with fever and increasing abdominal distention. An abdominal CT scan showed an obstructing foreign body in the small bowel.
Nancy Staggers, PhD, RN| October 1, 2017
Hospitalized with sepsis secondary to an infected IV line through which she was receiving treprostnil (a high-alert medication used to treat pulmonary hypertension), a woman was transferred to interventional radiology for placement of a new permanent catheter once the infection cleared. Sign-off between departments included a warning not to flush the line since it would lead to a dangerous overdose. However, while attempting to identify an infusion pump alarm, a radiology technician accidentally flushed the line, which led to a near code situation.
Vinod K. Bhutani, MD, and Ronald J. Wong| October 1, 2017
A newborn with elevated total serum bilirubin (TSB) due to hemolytic disease was placed on a mattress with embedded phototherapy lights for treatment, but the TSB continued to climb. The patient was transferred to the neonatal ICU for an exchange transfusion. The neonatologist requested testing of the phototherapy lights, and their irradiance level was found to be well below the recommended level. The lights were replaced, the patient's TSB level began to drop, and the exchange transfusion was aborted.
Lekshmi Santhosh, MD, and V. Courtney Broaddus, MD| June 1, 2017
A woman with pneumothorax required urgent chest tube placement. After she showed improvement during her hospital stay, the pulmonary team requested the tube be disconnected and clamped with a follow-up radiograph 1 hour later. However, 3 hours after the tube was clamped, no radiograph had been done and the patient was found unresponsive, in cardiac arrest.
Roy Ilan, MD, MSc| May 1, 2013
A woman was emergently admitted for surgery for acute appendicitis. Although the patient had a chest port for breast cancer chemotherapy, the surgeon demanded that a peripherally inserted central catheter (PICC) be placed. The patient developed blood clots from the PICC, and surgery was cancelled. Significant complications, including perforation, peritonitis, and prolonged hospitalization, arose from managing the appendicitis conservatively.
Jean L. Holley, MD | October 1, 2010
A man with end-stage renal disease on hemodialysis was dialyzed with equipment that had been inappropriately reused, exposing the patient to another patient's blood numerous times.
D. John Doyle, MD, PhD | August 21, 2005
Following surgery, a woman receives morphine via a patient-controlled analgesia (PCA) pump. A few hours after arriving on the floor, she is found barely breathing.
Richard H. White, MD | August 21, 2005
An intern increases a patient's warfarin dosage nightly based on subtherapeutic INR levels drawn each morning; after several days, the patient develops potentially life-threatening bleeding.
John Gosbee, MD, MS; Laura Lin Gosbee, MASc| February 1, 2003
An infusion pump being used for routine sedation in a child undergoing a magnetic resonance imaging (MRI) scan flew across the room and hit the MRI magnet, narrowly missing the child.