Skip to main content

WebM&M: Case Studies

WebM&M (Morbidity & Mortality Rounds on the Web) features expert analysis of medical errors reported anonymously by our readers. Spotlight Cases include interactive learning modules available for CME. Commentaries are written by patient safety experts and published monthly.

Have you encountered medical errors or patient safety issues? Submit your case below to help the medical community and to prevent similar errors in the future.

This Month's WebM&Ms

Update Date: May 16, 2022
Garima Agrawal, MD, MPH, and Mithu Molla, MD, MBA | May 16, 2022

This WebM&M describes two cases involving patients who became unresponsive in unconventional locations – inside of a computed tomography (CT) scanner and at an outpatient transplant clinic – and strategies to ensure that all healthcare teams are... Read More

Alexandria DePew, MSN, RN, James Rice, & Julie Chou, BSN | May 16, 2022

This WebM&M describes two incidences of the incorrect patient being transported from the Emergency Department (ED) to other parts of the hospital for tests or procedures. In one case, the wrong patient was identified before undergoing an... Read More

Have you encountered medical errors or patient safety issues?
Have you encountered medical errors or patient safety issues? Submit your case below to help the medical community and to prevent similar errors in the future.

All WebM&M: Case Studies (8)

1 - 8 of 8 WebM&M Case Studies
Cynthia Li, PharmD, and Katrina Marquez, PharmD| July 28, 2021

This commentary presents two cases highlighting common medication errors in retail pharmacy settings and discusses the importance of mandatory counseling for new medications, use of standardized error reporting processes, and the role of clinical decision support systems (CDSS) in medical decision-making and ensuring medication safety.

A 74-year-old male with a history of hypertension, hyperlipidemia, paroxysmal atrial fibrillation, coronary artery disease, congestive heart failure with an EF of 45%, stage I chronic kidney disease and gout presented for a total hip replacement. He had multiple home medications and was also on Warfarin, which was held appropriately prior to the surgery.  A Type and Cross for blood request was sent along with baseline labs; however, there was a mislabeling error on one of the samples causing a delay in the blood getting to the operating room resulting in the medical team initiating a massive transfusion protocol when the patient became hypotensive.
Take the Quiz
Christopher F. Janowak, MD, FACS, and Lauren M. Janowak, RN, BSN, CCRN| October 30, 2019
Two patients arrived at the Emergency Department (ED) at the same time with major trauma. Both patients were unidentified and were given "Doe" names. Patient 1 was quickly sent to the operating room (OR) but the ED nurse incorrectly gave him Patient 2's "Doe" name. The OR nurse only realized there was a problem when blood arrived with Patient 1's correct "Doe" name, requiring multiple phone calls with the ED, laboratory, and surgeon to correctly identify the patient.
Michael J. Barrington, MBBS, PhD, and Yoshiaki Uda, MBBS| April 1, 2017
An older woman admitted to the medical-surgical ward with multiple right-sided rib fractures received a paravertebral block to control the pain. After the procedure, the anesthesiologist realized that the block had been placed on the wrong side. The patient required an additional paravertebral block on the correct side, which increased her risk of complications and exposed her to additional medication.
Ross Koppel, PhD| April 1, 2009
A patient hospitalized with Pneumocystis jiroveci pneumonia and advanced AIDS is given another patient's malignant biopsy results, leading his primary physician to mistakenly recommend hospice care.
Albert W. Wu, MD, MPH; Peter J. Pronovost, MD, PhD| January 1, 2004
A patient receiving end-of-life care, whose code status was DNR, encounters a potentially life-threatening medication error.
Marilynn M. Rosenthal, PhD| July 1, 2003
An anxious patient awaiting ambulatory surgery is mistakenly put on the wrong operating table.