This Month's WebM&Ms

Update Date: May 16, 2022
Garima Agrawal, MD, MPH, and Mithu Molla, MD, MBA | May 16, 2022

This WebM&M describes two cases involving patients who became unresponsive in unconventional locations – inside of a computed tomography (CT) scanner and at an outpatient transplant clinic – and strategies to ensure that all healthcare teams are... Read More

Alexandria DePew, MSN, RN, James Rice, & Julie Chou, BSN | May 16, 2022

This WebM&M describes two incidences of the incorrect patient being transported from the Emergency Department (ED) to other parts of the hospital for tests or procedures. In one case, the wrong patient was identified before undergoing an... Read More

Have you encountered medical errors or patient safety issues?
Have you encountered medical errors or patient safety issues? Submit your case below to help the medical community and to prevent similar errors in the future.

All WebM&M: Case Studies (18)

1 - 18 of 18 WebM&M Case Studies
Robin Aldwinckle, MD and Edmund Florendo, MD| October 27, 2021

A 78-year-old woman with macular degeneration presented for a pars plana vitrectomy (PPV) under monitored anesthesia care (MAC) with an eye block. At this particular hospital, eye cases under MAC are typically performed with an eye block by the surgeon after the anesthesiologist has administered some short-acting sedation, commonly with remifentanil. On this day, there was a shortage of premixed remifentanil and the resident – who was unfamiliar with the process of drug dilution – incorrectly diluted the remifentanil solution. Shortly after receiving sedation, the patient became unresponsive, and a code was called. The commentary addresses the challenges of drug dilution and strategies to reduce dilutional errors and prioritize patient safety.

Kristine Chin, PharmD, Van Chau, PharmD, Hannah Spero, MSN, APRN, and Jessamyn Phillips, DNP | September 30, 2020

This case involves a 65-year-old woman with ongoing nausea and vomiting after an uncomplicated hernia repair who was mistakenly prescribed topiramate (brand name Topamax, an anticonvulsant and nerve pain medication) instead of trimethobenzamide (brand name Tigan, an antiemetic) by the outpatient pharmacy. The commentary uses the Swiss Cheese Model to discuss the safety challenges of “look-alike, sound-alike” (LASA) medications, the importance of phyiscians employing “soft” skills during medication dispensing, and how medication administration errors can occur in outpatient pharmacy settings, despite multiple opportunities for cross-verification. 

Daniel D. Nguyen, PharmD, Thomas A. Harper, MPH, CPhT, FCSHP and Ryan Cello, PharmD | July 29, 2020

A patient was mistakenly administered intravenous fentanyl which was leftover from a previous patient and not immediately wasted. Experts recommend the best practice for the safe disposal, or “waste”, of medications in the surgical setting is to either waste any leftover product immediately after administration or to fully document all waste at the end of the case.This commentary discusses the policies and procedures addressing wasting of medication by anesthesiologists, approaches to reduce medication administration errors, and the importance identifying process gaps that could lead to potential diversion.  

Janeane Giannini, PharmD, Melinda Wong, PharmD, William Dager, PharmD, Scott MacDonald, MD, and Richard H. White, MD | June 24, 2020
A male patient with history of femoral bypasses underwent thrombolysis and thrombectomy for a popliteal artery occlusion. An error in the discharge education materials resulted in the patient taking incorrect doses of rivaroxaban post-discharge, resulting in a readmission for recurrent right popliteal and posterior tibial occlusion. The commentary discusses the challenges associated with prescribing direct-action oral anticoagulants (DOACs) and how computerized clinical decision support tools can promote adherence to guideline recommendations and mitigate the risk of error, and how tools such as standardized teaching materials and teach-back can support patient understanding of medication-related instructions.
Erika Cutler, PharmD, and Delani Gunawardena, MD | December 18, 2019
A 55-year-old man visited his oncologist for a follow-up appointment after completing chemotherapy and reported feeling well with his abdominal and bony pain well controlled with opioid therapy.  At the end of the visit, his oncologist reordered his pain medication and, due to a best practice alert, also prescribed naloxone but failed to provide any instruction on its use. Later that day, the patient took the naloxone along with his opioid pain medication and within a minute experienced severe abdominal and bony pain, requiring admission to the emergency department.
Adam Wright, PhD, and Gordon Schiff, MD| October 30, 2019
Following resection of colorectal cancer, a hospitalized elderly man experienced a pulmonary embolism, which was treated with rivaroxaban. Upon discharge home, he received two separate prescriptions for rivaroxaban (per protocol): one for 15 mg twice daily for 10 days, and then 20 mg daily after that. Ten days later, the patient's wife returned to the pharmacy requesting a refill. On re-reviewing the medications with her, the pharmacist discovered the patient had been taking both prescriptions (a total daily dose of 50 mg daily). This overdose placed him at very high risk for bleeding complications.
Take the Quiz
Nicole M. Acquisto, PharmD, and Daniel J. Cobaugh, PharmD| March 1, 2019
Seen in the emergency department, a man with insulin-dependent diabetes mellitus had not taken insulin for 3 days. His blood glucose levels were in the 800s with an anion-gap acidosis and positive beta hydroxybutyrate. While awaiting an ICU bed for treatment of diabetic ketoacidosis, the patient received fluids, an insulin drip was started, and blood glucose levels were monitored hourly. When lab results showed he was improving, the team decided to convert his insulin drip to subcutaneous long-acting insulin. However, both the intern and the resident ordered 50 units of insulin, and the patient received both doses—causing his blood glucose level to dip into the 30s.
Helen Pervanas, PharmD, RPh, and David VanValkenburgh| August 1, 2018
Admitted to different hospitals multiple times for severe hypoglycemia, an older man underwent an extensive workup that did not identify a corresponding diagnosis. During his third hospitalization in 6 weeks, once his glucose level normalized, the care team believed the patient was ready for discharge, but the consulting endocrinologist asked the family to bring in all the patients' medication bottles. The family returned with 12 different medications, none of which were labeled as an oral hypoglycemic agent. The resident used the codes on the tablets to identify them and discovered that one of the medications, labeled an antihypertensive, actually contained oral hypoglycemic pills. As the patient had no history of diabetes, this likely represented a pharmacy filling error.
Jerod Nagel, PharmD, and Eric Nguyen| October 1, 2015
A woman who had recently had her left lung removed for aspergilloma presented to the outpatient clinic with pain, redness, and pus draining from her sternotomy site. She was admitted for surgical debridement and prescribed IV liposomal amphotericin B for aspergillus. Hours into the IV infusion, the patient developed nausea, vomiting, sweating, and shivering, and it was discovered that she had been given conventional amphotericin B at the dose intended for the liposomal formulation, representing a 5-fold overdose.
Robert L. Poole, PharmD; Tessa Dixon, PharmD| December 1, 2010
Following a vehicle collision, a man admitted to the hospital was given a twofold overdose of dexamethasone, due to confusion about administration instructions on a multidose vial.
Beth Devine, PharmD, MBA, PhD| April 1, 2010
A medication dispensing error causes nausea, sweating, and irregular heartbeat in an elderly man with a history of cardiac arrhythmia. Investigation reveals that the patient was given thyroid replacement medication instead of antiarrhythmic medication.
William W. Churchill, MS, RPh; Karen Fiumara, PharmD| April 1, 2009
A powerful anti-clotting medication is ordered for a patient admitted for coronary intervention. Due to a forcing function in the computer order entry system, the intern enters an arbitrary maintenance infusion rate, assuming that the pharmacy will fix it if it is wrong. The pharmacy dispenses it as written, and the nurse administers it—underdosing the patient by a factor of 40.
Eric G. Poon, MD, MPH| September 1, 2007
Hospitalized for surgery, a woman with a history of seizures was given an overdose of the wrong medicine due to multiple errors, including an inaccurate preadmission medication list, failure to verify medication history, and uncoordinated information systems.
Richard Hellman, MD| March 1, 2007
For a woman with insulin-dependent diabetes mellitus, the admitting medical team ordered sliding scale insulin. Her blood glucose levels became very difficult to control, and she developed diabetic ketoacidosis. In the morning, the physician instituted a more appropriate insulin regimen.
Robert J. Weber, MS, RPh| May 1, 2006
A pharmacist mistakenly dispenses Polycitra instead of Bicitra, and a patient winds up with severe hyperkalemia and hyperglycemia.
Timothy S. Lesar, PharmD| November 1, 2003
An unclear verbal order leads to administration of the wrong drug.