Sarina Fazio, PhD, RN, Emma Blackmon, PhD, RN, Amy Doroy, PhD, RN, Ai Nhat Vu and Paul MacDowell, PharmD. | May 26, 2021

A 64-year-old woman was admitted to the hospital for aortic valve replacement and aortic aneurysm repair. Following surgery, she became hypotensive and was given intravenous fluid boluses and vasopressor support with norepinephrine. On postoperative day 2, a fluid bolus was ordered; however, the fluid bag was attached to the IV line that had the vasopressor at a Y-site and the bolus was initiated. The error was recognized after 15 minutes of infusion, but the patient had ongoing hypotension following the inadvertent bolus. The commentary summarizes the common errors associated with administration of multiple intravenous infusions in intensive care settings and gives recommendations for reducing errors associated with co-administration of infusions.