Skip to main content

WebM&M: Case Studies

WebM&M (Morbidity & Mortality Rounds on the Web) features expert analysis of medical errors reported anonymously by our readers. Spotlight Cases include interactive learning modules available for CME. Commentaries are written by patient safety experts and published monthly.

Have you encountered medical errors or patient safety issues? Submit your case below to help the medical community and to prevent similar errors in the future.

This Month's WebM&Ms

Update Date: August 5, 2022
Samson Lee, PharmD, and Mithu Molla, MD, MBA | August 5, 2022

This WebM&M highlights two cases where home diabetes medications were not reviewed during medication reconciliation and the preventable harm that could have occurred. The commentary discusses the importance of medication reconciliation, how to... Read More

Have you encountered medical errors or patient safety issues?
Have you encountered medical errors or patient safety issues? Submit your case below to help the medical community and to prevent similar errors in the future.

All WebM&M: Case Studies (4)

1 - 4 of 4 WebM&M Case Studies
Catherine Chia, MD and Mithu Molla, MD, MBA | May 27, 2020
A 55-year old man was admitted to the hospital for pneumonia requiring intravenous antibiotics. After three intravenous lines infiltrated, the attending physician on call gave a verbal order to have a percutaneous intravenous central venous catheter placed by interventional radiology the next morning. However, the nurse on duty incorrectly entered an order for a tunneled dialysis catheter, and the radiologist then inserted the wrong type of catheter. The commentary explores safety issues with verbal orders and interventional radiology procedures.
by Kristin E. Sandau, PhD, RN, and Marjorie Funk, PhD, RN| April 1, 2019
An elderly woman with a history of dementia, chronic obstructive pulmonary disease, hypertension, and congestive heart failure (CHF) was brought to the emergency department and found to meet criteria for sepsis. Due to her CHF, she was admitted to a unit with telemetry monitoring, which at this institution was performed remotely. When the nurse came to check the patient's vital signs several hours later, she found the patient to be unresponsive and apneic, with no palpable pulse. A Code Blue was called, but the patient died. Although the telemetry technician had recognized progressive bradycardia and called the hospital floor several minutes before the code, he was placed on hold because the nurse was busy with another patient. While he was holding, he observed worsening bradycardia, eventually transitioning to asystole, and tried to redial the unit, but no one answered.
Elizabeth Manias, PhD, RN, MPharm| October 1, 2012
After having a seizure in the emergency department, a woman was to receive intravenous administration of an antiseizure medication. The nurse misread the medication order, gathered 32 vials of the medication, and administered a 10-fold overdose to the patient, who died several minutes later.
Tess Pape, PhD, RN, CNOR| February 1, 2006
Bypassing the safeguards of an automated dispensing machine in a skilled nursing facility, a nurse administers medications from a portable medication cart. A non-diabetic patient receives insulin by mistake, which requires his admission to intensive care and delays his chemotherapy for cancer.