Garima Agrawal, MD, MPH, and Mithu Molla, MD, MBA | May 16, 2022

This WebM&M describes two cases involving patients who became unresponsive in unconventional locations – inside of a computed tomography (CT) scanner and at an outpatient transplant clinic – and strategies to ensure that all healthcare teams are... Read More

Alexandria DePew, MSN, RN, James Rice, & Julie Chou, BSN | May 16, 2022

This WebM&M describes two incidences of the incorrect patient being transported from the Emergency Department (ED) to other parts of the hospital for tests or procedures. In one case, the wrong patient was identified before undergoing an... Read More

Have you encountered medical errors or patient safety issues?
Have you encountered medical errors or patient safety issues? Submit your case below to help the medical community and to prevent similar errors in the future.

All WebM&M: Case Studies (41)

1 - 20 of 41 WebM&M Case Studies
Marissa G. Vadi, MD, MPH, and Mathew R. Malkin, MD | October 27, 2021

A 6-week-old infant underwent a craniotomy and excision of abnormal brain tissue for treatment of hemimegalencephaly and epilepsy. A right femoral central venous catheter and an arterial catheter were inserted, as well as 22-gauge intravenous catheter inserted into the external jugular vein, which was covered with surgical drapes.  During the surgical procedure, the neurosurgeon adjusted the patient’s head, displacing the external jugular intravenous catheter into the subcutaneous tissue.  The catheter’s dislodgment went unnoticed due to its position underneath the surgical drapes. The commentary discusses the importance intraoperative monitoring of intravenous catheters and the use of surgical safety checklists to improve communication and prevent surgical complications.

Claire Manske, MD | August 26, 2020

A 56-year-old female received a digital tourniquet around the base of her left big toe during an ablation and excision of a deformed in-grown toenail. After the procedure, a dressing was applied and the patient was discharged 4 hours later. During the follow-up visit two-days later, the dressing was removed and revealed that the tourniquet was still in place and constricting the toe. The toe became necrotic and developed gangrene, and was amputated. The commentary discusses the safe use of digital tourniquets, the importance of including tourniquets in the surgical count process, and ensuring tourniquets are removed in a timely manner.

Mikael Broman, MD, PhD| April 29, 2020
A 54-year old women with chronic obstructive pulmonary disease was admitted for chronic respiratory failure. Due to severe hypoxemia, she was intubated, mechanically ventilated and required extracorporeal membrane oxygenation (ECMO). During the hospitalization, she developed clotting problems, which necessitated transfer to the operating room to change one of the ECMO components. On the way back to the intensive care unit, a piece of equipment became snagged on the elevator door and the system alarmed. The perfusionist arrived 30-minutes later and realized that the ECMO machine was introducing room air to the patient’s circulation, leading to air embolism. The patient became severely hypotensive and bradycardic, and despite aggressive attempts at resuscitation, she died.
C. Craig Blackmore, MD, MPH| March 1, 2019
A woman with multiple myeloma required placement of a central venous catheter for apheresis. The outpatient oncologist intended to order a nontunneled catheter via computerized provider order entry but accidentally ordered a tunneled catheter. The interventional radiologist thought the order was unusual but didn't contact the oncologist. A tunneled catheter was placed without complications. When the patient presented for apheresis, providers recognized the wrong catheter had been placed, and the patient underwent an additional procedure.
In a simulated cardiac resuscitation case of a 5-year-old boy found pulseless and apneic in the bathtub by a parent, many interprofessional teams had difficulty with resuscitation due to a lack of interoperability between the prestocked disposable laryngoscope blades and handles on the Broselow cart (a proprietary system designed to facilitate finding appropriate-sized equipment for pediatric patients requiring lifesaving interventions) with the emergency department's actual stock of blades and handles. This incompatibility led to significant delays and some failures to intubate. Teams often did not recognize the incompatibility and spent unnecessary time replacing batteries while others called for backup airway teams.
Rita L. McGill, MD, MS| July 1, 2018
Admitted to the hospital with an ulcer on his right foot, a man with diabetes and stage IV chronic kidney disease had an MRI concerning for osteomyelitis, and a bone biopsy showed chronic inflammation with cultures positive for methicillin-sensitive Staphylococcus aureus. To administer outpatient parenteral antimicrobial therapy, interventional radiology attempted to place a peripherally inserted central catheter (PICC) in the right brachial vein multiple times but failed. They then placed it in the left brachial vein. The patient completed 6 weeks of antibiotic therapy and wound care, and the PICC was removed. Five months later with worsening renal function and hyperphosphatemia, the patient required dialysis access, but he was not a candidate for arteriovenous fistula placement since the many venipuncture attempts during PICC placement resulted in poor vein quality.
Deborah Debono, PhD, RN, and Tracy Levett-Jones, PhD, RN| July 1, 2018
A young adult with a progressive neurological disorder presented to an emergency department from a nursing home with a dislodged GJ tube. As a workaround to maintain patency when the GJ tube was dislodged, nursing home staff had inserted a Foley catheter into the ostomy, inflated the Foley bulb in the stomach, and tied the distal portion of the catheter in a loose knot. When the patient went to interventional radiology for new GJ tube placement, clinicians found no Foley but inserted a new GJ tube. Discharged to the nursing home, the patient was readmitted 2 days later with fever and increasing abdominal distention. An abdominal CT scan showed an obstructing foreign body in the small bowel.
Jamie M. Robertson, PhD, MPH, and Charles N. Pozner, MD| April 1, 2018
A clinical team decided to use a radial artery approach for cardiac catheterization in a woman with morbid obesity. It took multiple attempts to access her radial artery. After catheter insertion, she experienced pain and pressure in her arm and chest. Review of the angiogram demonstrated the presence of an air embolism in the left coronary artery, introduced during the catheter insertion. Due to the difficulty of the procedure, the technician had failed to hold the syringe at the proper angle and introduced an air bubble into the patient's vessel.
Nancy Staggers, PhD, RN| October 1, 2017
Hospitalized with sepsis secondary to an infected IV line through which she was receiving treprostnil (a high-alert medication used to treat pulmonary hypertension), a woman was transferred to interventional radiology for placement of a new permanent catheter once the infection cleared. Sign-off between departments included a warning not to flush the line since it would lead to a dangerous overdose. However, while attempting to identify an infusion pump alarm, a radiology technician accidentally flushed the line, which led to a near code situation.
Vinod K. Bhutani, MD, and Ronald J. Wong| October 1, 2017
A newborn with elevated total serum bilirubin (TSB) due to hemolytic disease was placed on a mattress with embedded phototherapy lights for treatment, but the TSB continued to climb. The patient was transferred to the neonatal ICU for an exchange transfusion. The neonatologist requested testing of the phototherapy lights, and their irradiance level was found to be well below the recommended level. The lights were replaced, the patient's TSB level began to drop, and the exchange transfusion was aborted.
Lekshmi Santhosh, MD, and V. Courtney Broaddus, MD| June 1, 2017
A woman with pneumothorax required urgent chest tube placement. After she showed improvement during her hospital stay, the pulmonary team requested the tube be disconnected and clamped with a follow-up radiograph 1 hour later. However, 3 hours after the tube was clamped, no radiograph had been done and the patient was found unresponsive, in cardiac arrest.
Barbara Haas, MD, PhD, and Lesley Gotlib Conn, PhD| May 1, 2017
Admitted to the ICU with septic shock, a man with a transplanted kidney developed hypotension and required new central venous access. Since providers anticipated using the patient's left internal jugular vein catheter for re-starting hemodialysis (making it unsuitable to use for resuscitation), the ICU team placed the central line in the right femoral vein. However, they failed to recognize that his transplanted kidney was on the right side, which meant that femoral catheter placement on that side was contraindicated.
A man with a history of cardiac disease was brought to the emergency department for septic shock of possible intra-abdominal origin. A vasopressor was ordered. However, rather than delivering it through a central line, the norepinephrine was infused through a peripheral line. The medication extravasated into the subcutaneous tissue of the patient's arm. Despite attempts to salvage the patient's wrist and fingers, three of his fingertips had to be amputated.
Vineet Chopra, MD, MSc| February 1, 2016
Hospitalized with poorly controlled diabetes, a man had a peripherally inserted central catheter (PICC) placed for intravenous pain medications, intravenous fluids, and parenteral nutrition. The next day, the patient complained of headache, unilateral vision loss, and left-sided tingling and numbness. Misplacement of the PICC in a left-sided superior vena cava had led to embolic strokes.
Diane K. Newman, DNP, MSN; Robyn Strauss, MSN; Liza Abraham, CRNP; and Bridget Major-Joynes, MSN, RN| June 1, 2015
A hospitalized older man with a complicated medical history had not voided in several hours. The patient voided just prior to catheter insertion, which produced no urine, and the nurse assumed that meant the patient's bladder was empty. Two hours later the patient complained of discomfort and a blood clot was found in his tubing. Continuous bladder irrigation was ordered, but the pain became worse. Urgent consultation by urology revealed that the urinary catheter was not in the bladder.
Dustin W. Ballard, MD, MBE; David R. Vinson, MD; and Dustin G. Mark, MD| May 1, 2015
A man with a history of poorly controlled diabetes and pancreatic insufficiency was found unresponsive. Paramedics transported him to the emergency department, where a resident placed a right internal jugular line for access but was unable to confirm placement. The resident pulled the line, opened a second line insertion kit, started over, and confirmed placement with ultrasound. The patient went into cardiac arrest, and a chest radiograph noted a retained guidewire in the pulmonary artery.
Ayse P. Gurses, PhD, and Peter Doyle, PhD| December 1, 2014
An elderly man was being prepared for discharge after being hospitalized for an exacerbation of congestive heart failure. His nurse failed to notice that the tubing of the patient's sequential compression devices (in place to prevent DVT) was caught on the bed wheel and had unlocked the bed when she raised it. When the patient attempted to get up later, the bed rolled out from under him and he fell, breaking his hip. One week after surgery, the patient experienced a cardiac arrest from a massive pulmonary embolism and died.
Michelle Feil, MSN, RN| June 1, 2014
Following removal of a central venous catheter placed during his admission for a prolonged course of intravenous antibiotics, a young man with a history of Behçet disease was discharged from the hospital. Shortly thereafter, he presented to the emergency department with acute onset shortness of breath and a "whistling sound" coming from his neck. Diagnosed with air embolism, he was admitted to the ICU.
Roy Ilan, MD, MSc| May 1, 2013
A woman was emergently admitted for surgery for acute appendicitis. Although the patient had a chest port for breast cancer chemotherapy, the surgeon demanded that a peripherally inserted central catheter (PICC) be placed. The patient developed blood clots from the PICC, and surgery was cancelled. Significant complications, including perforation, peritonitis, and prolonged hospitalization, arose from managing the appendicitis conservatively.
Sonia C. Swayze, RN, MA, and Angela James, RN, BSN| March 1, 2013
While drawing labs on a woman admitted after a lung transplant, a nurse failed to clamp the patient's large-bore central line, allowing air to enter the catheter. The patient suffered a cerebral air embolism and was transferred to the ICU for several days.