Skip to main content

WebM&M: Case Studies

WebM&M (Morbidity & Mortality Rounds on the Web) features expert analysis of medical errors reported anonymously by our readers. Spotlight Cases include interactive learning modules available for CME. Commentaries are written by patient safety experts and published monthly.

Have you encountered medical errors or patient safety issues? Submit your case below to help the medical community and to prevent similar errors in the future.

This Month's WebM&Ms

Update Date: September 27, 2023
Have you encountered medical errors or patient safety issues?
Have you encountered medical errors or patient safety issues? Submit your case below to help the medical community and to prevent similar errors in the future.

All WebM&M: Case Studies (35)

Displaying 1 - 20 of 35 Results
Christian Bohringer, MBBS and Griffin Lee, MD| June 28, 2023

A 55-year-old man presented in hypotensive shock, presumably due to bacterial pneumonia superimposed on COPD. The nurse placed an arterial line appropriately in the patient’s radial artery for hemodynamic monitoring, but this line was inadvertently used to infuse an antibiotic. The patient experienced acute arterial thrombosis with resulting hand ischemia but responded to rapid thrombolytic and anticoagulant therapy. The commentary highlights several approaches to improving the safety of arterial injections, including the use of color-coded and Luer-specific connections, clear labeling of arterial lines, and the importance of monitoring arterial and central line pressures for signs of ischemia.

 

Commentary by Michael Leonardo Amashta, MD, and David K. Barnes, MD, FACEP | April 26, 2023

This case involves a procedural sedation error in a 3-year-old patient who presented to the Emergency Department with a left posterior hip dislocation. The commentary summarizes the indications and risks of procedural sedation in non-surgical settings and highlights the value of implementing system-wide safety protocols and practices to prevent medication administration errors during high-risk procedures.

Take the Quiz
Jonathan Trask, RN, Kathleen M. Carlsen, PA, Brooks T. Kuhn, MD| March 15, 2023

A 72-year-old man was diagnosed with COVID-19 pneumonia and ileus, and admitted to a specialized COVID care unit. A nasogastric tube (NGT) was placed, supplemental oxygen was provided, and oral feedings were withheld. Early in his hospital stay, the patient developed hyperactive delirium and pulled out his NGT. Haloperidol was ordered for use as needed (“prn”) and the nurse was asked to replace the NGT and confirm placement by X-ray. The bedside and charge nurses had difficulty placing the NGT and the X-ray confirmation was not done. Eight hours later, the patient became hypotensive and hypoxemic and emergent CT revealed a gastric perforation. The patient was transferred to the intensive care unit and ultimately required endotracheal intubation with mechanical ventilation. The commentary discusses the complications associated with nasogastric tube insertion, assessing and treating acute agitation secondary to delirium, and the importance of clear communication during shift changes and handoffs.

Take the Quiz
Garima Agrawal, MD, MPH, and Mithu Molla, MD, MBA | May 16, 2022

This WebM&M describes two cases involving patients who became unresponsive in unconventional locations – inside of a computed tomography (CT) scanner and at an outpatient transplant clinic – and strategies to ensure that all healthcare teams are prepared to deliver advanced cardiac life support (ACLS), such as the use of mock codes and standardized ACLS algorithms.

Nandakishor Kapa, M.D., and José A. Morfín, M.D.| February 23, 2022

A 69-year-old man with End-Stage Kidney Disease (ESKD) secondary to diabetes mellitus and hypertension, who had been on dialysis since 2014, underwent deceased donor kidney transplant. The case demonstrates the complex nature of management of allograft dysfunction due to vascular complications in a patient with deceased donor kidney transplant in the early post-transplant period. The commentary discusses how standardized follow-up imaging protocols can support early recognition and evaluation of allograft dysfunction due to vascular complications in kidney transplant recipients, as well the importance of team communication for patients requiring multiple interventions to reduce lag time in addressing further complications.

Melissa S. Wong, MD; Angelica Vivero, MD; Ellen B. Klapper, MD; and Kimberly D. Gregory, MD, MPH| July 2, 2019
First admitted to the hospital at 25 weeks of pregnancy for vaginal bleeding, a woman (G5 P2 A2) received 4 units of packed red blood cells and 2 doses of iron injections. She was discharged after 3 days with an improved hemoglobin level. At 35 weeks, she was admitted for an elective cesarean delivery. Intraoperatively, an upper uterine segment incision was made and the newborn was delivered in good condition. Immediately after, a subtotal hysterectomy was performed. The anesthesiologist noted that the patient was hypotensive; blood was transfused. A rash developed surrounding the transfusion site and widespread ecchymosis appeared as she became more unstable. Although physicians attempted to stabilize her with fluids and medications and cardiopulmonary resuscitation was performed for 60 minutes, the patient died.
Rommel Sagana, MD, and Robert C. Hyzy, MD| March 1, 2019
Following an elective carotid endarterectomy, an elderly woman was extubated in the operating room (OR) and brought to the recovery area. She soon developed respiratory distress necessitating urgent reintubation, which required multiple attempts. She was found to have an expanding neck hematoma, which was drained safely in the OR. Later that day after a half hour weaning trial, the respiratory therapist extubated the patient without checking for a cuff leak. Within 15 minutes, she developed acute shortness of breath and stridor, which rapidly progressed to hypoxemic respiratory failure. Urgent reintubation was difficult because her vocal cords were edematous.
C. Craig Blackmore, MD, MPH| March 1, 2019
A woman with multiple myeloma required placement of a central venous catheter for apheresis. The outpatient oncologist intended to order a nontunneled catheter via computerized provider order entry but accidentally ordered a tunneled catheter. The interventional radiologist thought the order was unusual but didn't contact the oncologist. A tunneled catheter was placed without complications. When the patient presented for apheresis, providers recognized the wrong catheter had been placed, and the patient underwent an additional procedure.
Elise Orvedal Leiten, MD, and Rune Nielsen, MD, PhD| January 1, 2019
Hospitalized in the ICU with hypoxic respiratory failure due to community-acquired pneumonia, an elderly man had increased pulmonary secretions on hospital day 2 for which the critical care provider decided to perform bedside bronchoscopy. Following the procedure, the patient was difficult to arouse, nearly apneic, and required intubation. The care team paused and discovered that after the patient had received 2 mg of intravenous midalozam, his IV line had been flushed with an additional 10 mg of the benzodiazepine, rather than the intended normal saline. This high dose of midazolam led to the respiratory failure requiring intubation. On top of that, instead of normal saline, lidocaine had been used for the lung lavage.
Maria J. Silveira, MD, MA, MPH| June 1, 2016
An older man with multiple medical conditions was found hypoxic, hypotensive, and tachycardic. He was taken to the hospital. Providers there were unable to determine the patient's wishes for life-sustaining care, and, unaware that he had previously completed a DNR/DNI order, they placed him on a mechanical ventilator.
Mark W. Scerbo, PhD, and Alfred Z. Abuhamad, MD| January 1, 2015
A woman who had an uncomplicated pregnancy and normal labor with no apparent signs of distress delivered a cyanotic, flaccid infant requiring extensive resuscitation. Although fetal heart rate tracings had shown signs of moderate-to-severe fetal distress for 90 minutes prior to delivery, clinicians did not notice the abnormalities on the remote centralized monitor, which displayed 16 windows, each for a different patient.
Matthias Görges, PhD, and J. Mark Ansermino, MBBCh, MSc| September 1, 2014
A man with atrial fibrillation underwent ablation in the catheterization laboratory under general endotracheal anesthesia. The patient was extremely stable during the 7-hour procedure with vital signs hardly changing over time. Inadvertently, the noninvasive blood pressure measurement stopped recording for 1 hour but went unnoticed. After the error was discovered, the case continued without any problems and the patient was discharged home the next day as planned.
Delphine Tuot, MDCM, MAS| September 1, 2014
A patient with ALS was hospitalized with presumed pneumonia and sepsis. Although he was treated with broad-spectrum antibiotics and fluid resuscitation, additional potassium was administered due to his potassium level remaining low. The patient went into cardiac arrest and resuscitation attempts were unsuccessful.
Raymond L. Fowler, MD, and Melanie J. Lippmann, MD| August 21, 2014
During a code blue, an intraosseous line was placed in the left tibia of an elderly woman after several unsuccessful attempts to obtain peripheral venous access. Following chest compressions and advanced cardiovascular life support protocol, spontaneous circulation returned and the patient was transferred to the intensive care unit. A few hours later, the left leg was dusky purple with sluggish distal pulses.
Don C. Rockey, MD| August 21, 2014
Presenting with jaundice and epigastric pain, a woman with a history of multiple malignancies was admitted directly for an ultrasound-guided liver biopsy. After the procedure, the patient had low blood pressure and complained of new abdominal pain, which worsened over the next 2 hours. The bedside nurse soon found the patient unresponsive.
Margaret C. Fang, MD, MPH| December 1, 2013
Two days after knee replacement surgery, a woman with a history of deep venous thrombosis receiving pain control via epidural catheter was restarted on her outpatient dose of rivaroxaban (a newer oral anticoagulant). Although the pain service fellow scanned the medication list for traditional anticoagulants, he did not notice the patient was taking rivaroxaban before removing the epidural catheter, placing the patient at very high risk for bleeding.
Sonia C. Swayze, RN, MA, and Angela James, RN, BSN| March 1, 2013
While drawing labs on a woman admitted after a lung transplant, a nurse failed to clamp the patient's large-bore central line, allowing air to enter the catheter. The patient suffered a cerebral air embolism and was transferred to the ICU for several days.
Mark Ault, MD, and Bradley Rosen, MD, MBA| February 1, 2013
A woman found unresponsive at home presented to the ED via ambulance. The cardiology team used the central line placed during resuscitation to deliver medications and fluids during pacemaker insertion. Hours later, a chest radiograph showed whiteout of the right lung, and clinicians realized that the tip of the line was actually within the lung.
Debora Simmons, PhD, RN| September 1, 2011
Following surgery, a cancer patient was receiving total parenteral nutrition and lipids through a central venous catheter and pain control through an epidural catheter. A nurse mistakenly connected a new bottle of lipids to the epidural tubing rather than the central line, and the error was not noticed for several hours.
Nancy Spector, PhD, RN | March 1, 2011
While caring for a complex patient in the surgical intensive care unit, a nurse incorrectly set up the continuous renal replacement therapy (CRRT) machine, raising questions about how new nurses should be trained in high-risk procedures.