All WebM&M: Case Studies (58)

Displaying 1 - 20 of 58 WebM&M Case Studies
Megan Chalupsky, MD, Huixia Wei, MD, and Emily Marquet, MD| March 29, 2023

This patient with recently diagnosed adenocarcinoma of the esophagus underwent esophagoscopy with endoscopic ultrasound, which was complicated by thoracic esophageal perforation. The perforation was endoscopically closed during the procedure. However, there was a lack of clear communication regarding the operator’s confidence in the success of endoscopic closure and their recommendations for the modality and timing of follow-up imaging, which ultimately led to significant delays in patient care. The commentary discusses the importance of clear communication and hand-offs between proceduralists and other healthcare team members.

A 48-year-old obese man with a history of obstructive sleep apnea was placed under general anesthesia for corneal surgery. On completion of the operation, the patient was transferred to a motorized gurney to extubate him in a sitting position because the operating room (OR) table was too narrow. However, while the team was moving him from the OR table to the gurney, a nurse inadvertently pulled on the anesthetic machine hoses. The endotracheal tube became dislodged and the patient could not be ventilated. The commentary discusses considerations for regional versus general anesthesia and appropriate steps for extubation in obese and other high-risk patients, including the use of high flow nasal oxygen.

Jonathan Trask, RN, Kathleen M. Carlsen, PA, Brooks T. Kuhn, MD| March 15, 2023

A 72-year-old man was diagnosed with COVID-19 pneumonia and ileus, and admitted to a specialized COVID care unit. A nasogastric tube (NGT) was placed, supplemental oxygen was provided, and oral feedings were withheld. Early in his hospital stay, the patient developed hyperactive delirium and pulled out his NGT. Haloperidol was ordered for use as needed (“prn”) and the nurse was asked to replace the NGT and confirm placement by X-ray. The bedside and charge nurses had difficulty placing the NGT and the X-ray confirmation was not done. Eight hours later, the patient became hypotensive and hypoxemic and emergent CT revealed a gastric perforation. The patient was transferred to the intensive care unit and ultimately required endotracheal intubation with mechanical ventilation. The commentary discusses the complications associated with nasogastric tube insertion, assessing and treating acute agitation secondary to delirium, and the importance of clear communication during shift changes and handoffs.

Take the Quiz
Carla S. Martin, MSN, RN, CIC, CNL, NEA-BC, FACHE, Shannon K. Reese, BSN, RN, VABC, and Margaret Brown-McManus, MSN, RN, CNL | September 28, 2022

This case describes a 20-year-old woman was diagnosed with a pulmonary embolism and occlusive thrombus in the right brachial vein surrounding a  peripherally inserted central catheter (PICC) line (type, gauge, and length of time the PICC had been in place were not noted). The patient was discharged home but was not given any supplies for cleaning the PICC line, education regarding the signs of PICC line infection, or referral to home health services. During follow-up several days after discharge, the patient’s primary care provider noted that the PICC dressing was due to be changed and needed to be flushed, but the outpatient setting lacked the necessary supplies. An urgent referral to home health was placed, but the agency would be unable to attend to the patient for several days. The primary care provider changed the dressing, and the patient was referred to the emergency department for assessment. The commentary summarizes the risks of PICC lines, the role of infection prevention practices during the insertion and care of PICC lines, and the importance of patient education and skill assessment prior to discharge home with a PICC line.

David Barnes, MD and Joseph Yoon, MD | April 27, 2022

An 18-month-old girl presented to the Emergency Department (ED) after being attacked by a dog and sustaining multiple penetrating injuries to her head and neck. After multiple unsuccessful attempts to establish intravenous access, an intraosseous (IO) line was placed in the patient’s proximal left tibia to facilitate administration of fluids, blood products, vasopressors, and antibiotics.  In the operating room, peripheral intravenous (IV) access was eventually obtained after which intraoperative use of the IO line was restricted to a low-rate fluid infusion.  An hour into the operation, the anesthesiologist found her left calf to be warm and tense, presumably due to fluid extravasation from the IO line.  The IO line was removed, and the Orthopedic Surgery service was consulted intraoperatively due to concern for acute compartment syndrome.  Signs of compartment syndrome eventually resolved without any surgical intervention.  The commentary summarizes complications associated with IO lines, the importance of anticipating procedural complications, and methods to identify the signs and symptoms of acute compartment syndrome.

Take the Quiz
Marissa G. Vadi, MD, MPH, and Mathew R. Malkin, MD | October 27, 2021

A 6-week-old infant underwent a craniotomy and excision of abnormal brain tissue for treatment of hemimegalencephaly and epilepsy. A right femoral central venous catheter and an arterial catheter were inserted, as well as 22-gauge intravenous catheter inserted into the external jugular vein, which was covered with surgical drapes.  During the surgical procedure, the neurosurgeon adjusted the patient’s head, displacing the external jugular intravenous catheter into the subcutaneous tissue.  The catheter’s dislodgment went unnoticed due to its position underneath the surgical drapes. The commentary discusses the importance intraoperative monitoring of intravenous catheters and the use of surgical safety checklists to improve communication and prevent surgical complications.

Claire Manske, MD | August 26, 2020

A 56-year-old female received a digital tourniquet around the base of her left big toe during an ablation and excision of a deformed in-grown toenail. After the procedure, a dressing was applied and the patient was discharged 4 hours later. During the follow-up visit two-days later, the dressing was removed and revealed that the tourniquet was still in place and constricting the toe. The toe became necrotic and developed gangrene, and was amputated. The commentary discusses the safe use of digital tourniquets, the importance of including tourniquets in the surgical count process, and ensuring tourniquets are removed in a timely manner.

Catherine Chia, MD and Mithu Molla, MD, MBA | May 27, 2020
A 55-year old man was admitted to the hospital for pneumonia requiring intravenous antibiotics. After three intravenous lines infiltrated, the attending physician on call gave a verbal order to have a percutaneous intravenous central venous catheter placed by interventional radiology the next morning. However, the nurse on duty incorrectly entered an order for a tunneled dialysis catheter, and the radiologist then inserted the wrong type of catheter. The commentary explores safety issues with verbal orders and interventional radiology procedures.
Mikael Broman, MD, PhD| April 29, 2020
A 54-year old women with chronic obstructive pulmonary disease was admitted for chronic respiratory failure. Due to severe hypoxemia, she was intubated, mechanically ventilated and required extracorporeal membrane oxygenation (ECMO). During the hospitalization, she developed clotting problems, which necessitated transfer to the operating room to change one of the ECMO components. On the way back to the intensive care unit, a piece of equipment became snagged on the elevator door and the system alarmed. The perfusionist arrived 30-minutes later and realized that the ECMO machine was introducing room air to the patient’s circulation, leading to air embolism. The patient became severely hypotensive and bradycardic, and despite aggressive attempts at resuscitation, she died.
Neal L. Benowitz, MD| April 1, 2019
A woman who required oxygen at home via nasal cannula and used a continuous positive airway pressure (CPAP) machine at night was admitted for an exacerbation of chronic obstructive pulmonary disease without any signs of infection. During her hospital stay, she continued to require 5 liters of oxygen by nasal cannula. Although the patient had received smoking cessation education and no longer smoked regular cigarettes, she did continue to vape with an electronic cigarette (e-cigarette). Having not been told to avoid vaping in the hospital, the patient took a puff on her e-cigarette while she was receiving oxygen through her nasal cannula and sparked an explosion. She ripped off the nasal cannula, which had melted, and sustained burns to her face and hand, resulting in a prolonged hospitalization for burn care and extensive pain management.
C. Craig Blackmore, MD, MPH| March 1, 2019
A woman with multiple myeloma required placement of a central venous catheter for apheresis. The outpatient oncologist intended to order a nontunneled catheter via computerized provider order entry but accidentally ordered a tunneled catheter. The interventional radiologist thought the order was unusual but didn't contact the oncologist. A tunneled catheter was placed without complications. When the patient presented for apheresis, providers recognized the wrong catheter had been placed, and the patient underwent an additional procedure.
In a simulated cardiac resuscitation case of a 5-year-old boy found pulseless and apneic in the bathtub by a parent, many interprofessional teams had difficulty with resuscitation due to a lack of interoperability between the prestocked disposable laryngoscope blades and handles on the Broselow cart (a proprietary system designed to facilitate finding appropriate-sized equipment for pediatric patients requiring lifesaving interventions) with the emergency department's actual stock of blades and handles. This incompatibility led to significant delays and some failures to intubate. Teams often did not recognize the incompatibility and spent unnecessary time replacing batteries while others called for backup airway teams.
Deborah Debono, PhD, RN, and Tracy Levett-Jones, PhD, RN| July 1, 2018
A young adult with a progressive neurological disorder presented to an emergency department from a nursing home with a dislodged GJ tube. As a workaround to maintain patency when the GJ tube was dislodged, nursing home staff had inserted a Foley catheter into the ostomy, inflated the Foley bulb in the stomach, and tied the distal portion of the catheter in a loose knot. When the patient went to interventional radiology for new GJ tube placement, clinicians found no Foley but inserted a new GJ tube. Discharged to the nursing home, the patient was readmitted 2 days later with fever and increasing abdominal distention. An abdominal CT scan showed an obstructing foreign body in the small bowel.
Rita L. McGill, MD, MS| July 1, 2018
Admitted to the hospital with an ulcer on his right foot, a man with diabetes and stage IV chronic kidney disease had an MRI concerning for osteomyelitis, and a bone biopsy showed chronic inflammation with cultures positive for methicillin-sensitive Staphylococcus aureus. To administer outpatient parenteral antimicrobial therapy, interventional radiology attempted to place a peripherally inserted central catheter (PICC) in the right brachial vein multiple times but failed. They then placed it in the left brachial vein. The patient completed 6 weeks of antibiotic therapy and wound care, and the PICC was removed. Five months later with worsening renal function and hyperphosphatemia, the patient required dialysis access, but he was not a candidate for arteriovenous fistula placement since the many venipuncture attempts during PICC placement resulted in poor vein quality.
Jamie M. Robertson, PhD, MPH, and Charles N. Pozner, MD| April 1, 2018
A clinical team decided to use a radial artery approach for cardiac catheterization in a woman with morbid obesity. It took multiple attempts to access her radial artery. After catheter insertion, she experienced pain and pressure in her arm and chest. Review of the angiogram demonstrated the presence of an air embolism in the left coronary artery, introduced during the catheter insertion. Due to the difficulty of the procedure, the technician had failed to hold the syringe at the proper angle and introduced an air bubble into the patient's vessel.
Vinod K. Bhutani, MD, and Ronald J. Wong| October 1, 2017
A newborn with elevated total serum bilirubin (TSB) due to hemolytic disease was placed on a mattress with embedded phototherapy lights for treatment, but the TSB continued to climb. The patient was transferred to the neonatal ICU for an exchange transfusion. The neonatologist requested testing of the phototherapy lights, and their irradiance level was found to be well below the recommended level. The lights were replaced, the patient's TSB level began to drop, and the exchange transfusion was aborted.
Nancy Staggers, PhD, RN| October 1, 2017
Hospitalized with sepsis secondary to an infected IV line through which she was receiving treprostnil (a high-alert medication used to treat pulmonary hypertension), a woman was transferred to interventional radiology for placement of a new permanent catheter once the infection cleared. Sign-off between departments included a warning not to flush the line since it would lead to a dangerous overdose. However, while attempting to identify an infusion pump alarm, a radiology technician accidentally flushed the line, which led to a near code situation.
Lekshmi Santhosh, MD, and V. Courtney Broaddus, MD| June 1, 2017
A woman with pneumothorax required urgent chest tube placement. After she showed improvement during her hospital stay, the pulmonary team requested the tube be disconnected and clamped with a follow-up radiograph 1 hour later. However, 3 hours after the tube was clamped, no radiograph had been done and the patient was found unresponsive, in cardiac arrest.
Barbara Haas, MD, PhD, and Lesley Gotlib Conn, PhD| May 1, 2017
Admitted to the ICU with septic shock, a man with a transplanted kidney developed hypotension and required new central venous access. Since providers anticipated using the patient's left internal jugular vein catheter for re-starting hemodialysis (making it unsuitable to use for resuscitation), the ICU team placed the central line in the right femoral vein. However, they failed to recognize that his transplanted kidney was on the right side, which meant that femoral catheter placement on that side was contraindicated.