Skip to main content

WebM&M: Case Studies

WebM&M (Morbidity & Mortality Rounds on the Web) features expert analysis of medical errors reported anonymously by our readers. Spotlight Cases include interactive learning modules available for CME. Commentaries are written by patient safety experts and published monthly.

Have you encountered medical errors or patient safety issues? Submit your case below to help the medical community and to prevent similar errors in the future.

This Month's WebM&Ms

Update Date: April 26, 2023
Have you encountered medical errors or patient safety issues?
Have you encountered medical errors or patient safety issues? Submit your case below to help the medical community and to prevent similar errors in the future.

All WebM&M: Case Studies (14)

Displaying 1 - 14 of 14 WebM&M Case Studies
Jonathan Trask, RN, Kathleen M. Carlsen, PA, Brooks T. Kuhn, MD| March 15, 2023

A 72-year-old man was diagnosed with COVID-19 pneumonia and ileus, and admitted to a specialized COVID care unit. A nasogastric tube (NGT) was placed, supplemental oxygen was provided, and oral feedings were withheld. Early in his hospital stay, the patient developed hyperactive delirium and pulled out his NGT. Haloperidol was ordered for use as needed (“prn”) and the nurse was asked to replace the NGT and confirm placement by X-ray. The bedside and charge nurses had difficulty placing the NGT and the X-ray confirmation was not done. Eight hours later, the patient became hypotensive and hypoxemic and emergent CT revealed a gastric perforation. The patient was transferred to the intensive care unit and ultimately required endotracheal intubation with mechanical ventilation. The commentary discusses the complications associated with nasogastric tube insertion, assessing and treating acute agitation secondary to delirium, and the importance of clear communication during shift changes and handoffs.

Take the Quiz
David Barnes, MD and Joseph Yoon, MD | April 27, 2022

An 18-month-old girl presented to the Emergency Department (ED) after being attacked by a dog and sustaining multiple penetrating injuries to her head and neck. After multiple unsuccessful attempts to establish intravenous access, an intraosseous (IO) line was placed in the patient’s proximal left tibia to facilitate administration of fluids, blood products, vasopressors, and antibiotics.  In the operating room, peripheral intravenous (IV) access was eventually obtained after which intraoperative use of the IO line was restricted to a low-rate fluid infusion.  An hour into the operation, the anesthesiologist found her left calf to be warm and tense, presumably due to fluid extravasation from the IO line.  The IO line was removed, and the Orthopedic Surgery service was consulted intraoperatively due to concern for acute compartment syndrome.  Signs of compartment syndrome eventually resolved without any surgical intervention.  The commentary summarizes complications associated with IO lines, the importance of anticipating procedural complications, and methods to identify the signs and symptoms of acute compartment syndrome.

Take the Quiz
C. Craig Blackmore, MD, MPH| March 1, 2019
A woman with multiple myeloma required placement of a central venous catheter for apheresis. The outpatient oncologist intended to order a nontunneled catheter via computerized provider order entry but accidentally ordered a tunneled catheter. The interventional radiologist thought the order was unusual but didn't contact the oncologist. A tunneled catheter was placed without complications. When the patient presented for apheresis, providers recognized the wrong catheter had been placed, and the patient underwent an additional procedure.
Tara Kirkpatrick, MD, and Chad LaGrange, MD| February 1, 2016
Despite mechanical problems with the robotic arms during a robotic-assisted prostatectomy, the surgeon continued using the technology and completed the operation. Following the procedure, the patient developed serious bleeding requiring multiple blood transfusions, several additional surgeries, and a prolonged hospital stay.
Michele M. Pelter, RN, PhD, and Barbara J. Drew, RN, PhD| December 1, 2015
Following a non-ST segment elevation myocardial infarction, a man was admitted to the hospital and placed on a telemetry monitor. As the monitor was constantly sounding with "low voltage" and "asystole" alerts and the patient was well each time clinicians checked, they silenced the alarms. The patient was found dead 4 hours later.
Joseph I. Boullata, PharmD, RPh, BCNSP| April 1, 2013
A 3-year-old boy hospitalized with anemia who was on chronic total parenteral nutrition was given an admixture with a level of sodium 10-fold higher than intended. Despite numerous warnings and checks along the way, the error still reached the patient.
Chi-Tai Fang, MD, PhD| September 1, 2012
Admitted with a congestive heart failure exacerbation, an elderly man acquired an infection around his peripheral IV site, accompanied by fever, chills, and back pain. Likely secondary to the infected peripheral IV catheter, the patient had developed methicillin-resistant Staphylococcus aureus bacteremia and an epidural abscess.
Jean L. Holley, MD | October 1, 2010
A man with end-stage renal disease on hemodialysis was dialyzed with equipment that had been inappropriately reused, exposing the patient to another patient's blood numerous times.
Vesselin Dimov, MD| April 1, 2009
A premature infant had a PICC line placed for parenteral nutrition. During an attempt to remove it, the line broke. The infant had to be sent for surgical removal of the catheter and required an increased level of care, including ventilator support.
Richard H. White, MD | August 21, 2005
An intern increases a patient's warfarin dosage nightly based on subtherapeutic INR levels drawn each morning; after several days, the patient develops potentially life-threatening bleeding.
Jeremy P. Feldman, MD; Michael K. Gould, MD, MS | March 1, 2004
A central line placed incorrectly causes a patient to suffer permanent neurologic damage.