Skip to main content

WebM&M: Case Studies

WebM&M (Morbidity & Mortality Rounds on the Web) features expert analysis of medical errors reported anonymously by our readers. Spotlight Cases include interactive learning modules available for CME. Commentaries are written by patient safety experts and published monthly.

Have you encountered medical errors or patient safety issues? Submit your case below to help the medical community and to prevent similar errors in the future.

This Month's WebM&Ms

Update Date: March 15, 2023
Joy Chaudhry, PharmD, BCPS, BCCCP, Julie Chou BSN, RN, CNOR, Courtney Manning, PharmD, MBA, Minji Kim, RN, BSN, CNOR, and David Dakwa, PharmD, MBA, BCPS, BCSCP | March 15, 2023

This case focuses on immediate-use medication compounding in the operating room and how the process creates situations in which medication errors can occur. The commentary discusses strategies for safe perioperative compounding and the... Read More

Nisha Punatar, MD, Samson Lee, PharmD, BCACP, and Mithu Molla, MD, MBA | March 15, 2023

The cases described in this WebM&M reflect fragmented care with lapses in coordination and communication as well as failure to appropriately address medication discrepancies. These two cases involve duplicate therapy errors, which have the potential to cause... Read More

Have you encountered medical errors or patient safety issues?
Have you encountered medical errors or patient safety issues? Submit your case below to help the medical community and to prevent similar errors in the future.

All WebM&M: Case Studies (11)

Displaying 1 - 11 of 11 WebM&M Case Studies
Mikael Broman, MD, PhD| April 29, 2020
A 54-year old women with chronic obstructive pulmonary disease was admitted for chronic respiratory failure. Due to severe hypoxemia, she was intubated, mechanically ventilated and required extracorporeal membrane oxygenation (ECMO). During the hospitalization, she developed clotting problems, which necessitated transfer to the operating room to change one of the ECMO components. On the way back to the intensive care unit, a piece of equipment became snagged on the elevator door and the system alarmed. The perfusionist arrived 30-minutes later and realized that the ECMO machine was introducing room air to the patient’s circulation, leading to air embolism. The patient became severely hypotensive and bradycardic, and despite aggressive attempts at resuscitation, she died.
Neal L. Benowitz, MD| April 1, 2019
A woman who required oxygen at home via nasal cannula and used a continuous positive airway pressure (CPAP) machine at night was admitted for an exacerbation of chronic obstructive pulmonary disease without any signs of infection. During her hospital stay, she continued to require 5 liters of oxygen by nasal cannula. Although the patient had received smoking cessation education and no longer smoked regular cigarettes, she did continue to vape with an electronic cigarette (e-cigarette). Having not been told to avoid vaping in the hospital, the patient took a puff on her e-cigarette while she was receiving oxygen through her nasal cannula and sparked an explosion. She ripped off the nasal cannula, which had melted, and sustained burns to her face and hand, resulting in a prolonged hospitalization for burn care and extensive pain management.
C. Craig Blackmore, MD, MPH| March 1, 2019
A woman with multiple myeloma required placement of a central venous catheter for apheresis. The outpatient oncologist intended to order a nontunneled catheter via computerized provider order entry but accidentally ordered a tunneled catheter. The interventional radiologist thought the order was unusual but didn't contact the oncologist. A tunneled catheter was placed without complications. When the patient presented for apheresis, providers recognized the wrong catheter had been placed, and the patient underwent an additional procedure.
In a simulated cardiac resuscitation case of a 5-year-old boy found pulseless and apneic in the bathtub by a parent, many interprofessional teams had difficulty with resuscitation due to a lack of interoperability between the prestocked disposable laryngoscope blades and handles on the Broselow cart (a proprietary system designed to facilitate finding appropriate-sized equipment for pediatric patients requiring lifesaving interventions) with the emergency department's actual stock of blades and handles. This incompatibility led to significant delays and some failures to intubate. Teams often did not recognize the incompatibility and spent unnecessary time replacing batteries while others called for backup airway teams.
Nancy Staggers, PhD, RN| October 1, 2017
Hospitalized with sepsis secondary to an infected IV line through which she was receiving treprostnil (a high-alert medication used to treat pulmonary hypertension), a woman was transferred to interventional radiology for placement of a new permanent catheter once the infection cleared. Sign-off between departments included a warning not to flush the line since it would lead to a dangerous overdose. However, while attempting to identify an infusion pump alarm, a radiology technician accidentally flushed the line, which led to a near code situation.
Vinod K. Bhutani, MD, and Ronald J. Wong| October 1, 2017
A newborn with elevated total serum bilirubin (TSB) due to hemolytic disease was placed on a mattress with embedded phototherapy lights for treatment, but the TSB continued to climb. The patient was transferred to the neonatal ICU for an exchange transfusion. The neonatologist requested testing of the phototherapy lights, and their irradiance level was found to be well below the recommended level. The lights were replaced, the patient's TSB level began to drop, and the exchange transfusion was aborted.
Dustin W. Ballard, MD, MBE; David R. Vinson, MD; and Dustin G. Mark, MD| May 1, 2015
A man with a history of poorly controlled diabetes and pancreatic insufficiency was found unresponsive. Paramedics transported him to the emergency department, where a resident placed a right internal jugular line for access but was unable to confirm placement. The resident pulled the line, opened a second line insertion kit, started over, and confirmed placement with ultrasound. The patient went into cardiac arrest, and a chest radiograph noted a retained guidewire in the pulmonary artery.
Nancy Spector, PhD, RN | March 1, 2011
While caring for a complex patient in the surgical intensive care unit, a nurse incorrectly set up the continuous renal replacement therapy (CRRT) machine, raising questions about how new nurses should be trained in high-risk procedures.
Richard H. White, MD | August 21, 2005
An intern increases a patient's warfarin dosage nightly based on subtherapeutic INR levels drawn each morning; after several days, the patient develops potentially life-threatening bleeding.
Kay Ball, RN, MSA | October 1, 2004
While repositioning the trocar, a surgeon places the laparoscope on a tray sitting on the patient. When she picks it back up, she notices that the drape has melted and the patient has a second-degree burn.