Samson Lee, PharmD, and Mithu Molla, MD, MBA | August 5, 2022

This WebM&M highlights two cases where home diabetes medications were not reviewed during medication reconciliation and the preventable harm that could have occurred. The commentary discusses the importance of medication reconciliation, how to... Read More

Have you encountered medical errors or patient safety issues?
Have you encountered medical errors or patient safety issues? Submit your case below to help the medical community and to prevent similar errors in the future.

All WebM&M: Case Studies (20)

1 - 20 of 20 WebM&M Case Studies
Claire Manske, MD | August 26, 2020

A 56-year-old female received a digital tourniquet around the base of her left big toe during an ablation and excision of a deformed in-grown toenail. After the procedure, a dressing was applied and the patient was discharged 4 hours later. During the follow-up visit two-days later, the dressing was removed and revealed that the tourniquet was still in place and constricting the toe. The toe became necrotic and developed gangrene, and was amputated. The commentary discusses the safe use of digital tourniquets, the importance of including tourniquets in the surgical count process, and ensuring tourniquets are removed in a timely manner.

Catherine Chia, MD and Mithu Molla, MD, MBA | May 27, 2020
A 55-year old man was admitted to the hospital for pneumonia requiring intravenous antibiotics. After three intravenous lines infiltrated, the attending physician on call gave a verbal order to have a percutaneous intravenous central venous catheter placed by interventional radiology the next morning. However, the nurse on duty incorrectly entered an order for a tunneled dialysis catheter, and the radiologist then inserted the wrong type of catheter. The commentary explores safety issues with verbal orders and interventional radiology procedures.
Mikael Broman, MD, PhD| April 29, 2020
A 54-year old women with chronic obstructive pulmonary disease was admitted for chronic respiratory failure. Due to severe hypoxemia, she was intubated, mechanically ventilated and required extracorporeal membrane oxygenation (ECMO). During the hospitalization, she developed clotting problems, which necessitated transfer to the operating room to change one of the ECMO components. On the way back to the intensive care unit, a piece of equipment became snagged on the elevator door and the system alarmed. The perfusionist arrived 30-minutes later and realized that the ECMO machine was introducing room air to the patient’s circulation, leading to air embolism. The patient became severely hypotensive and bradycardic, and despite aggressive attempts at resuscitation, she died.
C. Craig Blackmore, MD, MPH| March 1, 2019
A woman with multiple myeloma required placement of a central venous catheter for apheresis. The outpatient oncologist intended to order a nontunneled catheter via computerized provider order entry but accidentally ordered a tunneled catheter. The interventional radiologist thought the order was unusual but didn't contact the oncologist. A tunneled catheter was placed without complications. When the patient presented for apheresis, providers recognized the wrong catheter had been placed, and the patient underwent an additional procedure.
Rita L. McGill, MD, MS| July 1, 2018
Admitted to the hospital with an ulcer on his right foot, a man with diabetes and stage IV chronic kidney disease had an MRI concerning for osteomyelitis, and a bone biopsy showed chronic inflammation with cultures positive for methicillin-sensitive Staphylococcus aureus. To administer outpatient parenteral antimicrobial therapy, interventional radiology attempted to place a peripherally inserted central catheter (PICC) in the right brachial vein multiple times but failed. They then placed it in the left brachial vein. The patient completed 6 weeks of antibiotic therapy and wound care, and the PICC was removed. Five months later with worsening renal function and hyperphosphatemia, the patient required dialysis access, but he was not a candidate for arteriovenous fistula placement since the many venipuncture attempts during PICC placement resulted in poor vein quality.
Deborah Debono, PhD, RN, and Tracy Levett-Jones, PhD, RN| July 1, 2018
A young adult with a progressive neurological disorder presented to an emergency department from a nursing home with a dislodged GJ tube. As a workaround to maintain patency when the GJ tube was dislodged, nursing home staff had inserted a Foley catheter into the ostomy, inflated the Foley bulb in the stomach, and tied the distal portion of the catheter in a loose knot. When the patient went to interventional radiology for new GJ tube placement, clinicians found no Foley but inserted a new GJ tube. Discharged to the nursing home, the patient was readmitted 2 days later with fever and increasing abdominal distention. An abdominal CT scan showed an obstructing foreign body in the small bowel.
Nancy Staggers, PhD, RN| October 1, 2017
Hospitalized with sepsis secondary to an infected IV line through which she was receiving treprostnil (a high-alert medication used to treat pulmonary hypertension), a woman was transferred to interventional radiology for placement of a new permanent catheter once the infection cleared. Sign-off between departments included a warning not to flush the line since it would lead to a dangerous overdose. However, while attempting to identify an infusion pump alarm, a radiology technician accidentally flushed the line, which led to a near code situation.
Vinod K. Bhutani, MD, and Ronald J. Wong| October 1, 2017
A newborn with elevated total serum bilirubin (TSB) due to hemolytic disease was placed on a mattress with embedded phototherapy lights for treatment, but the TSB continued to climb. The patient was transferred to the neonatal ICU for an exchange transfusion. The neonatologist requested testing of the phototherapy lights, and their irradiance level was found to be well below the recommended level. The lights were replaced, the patient's TSB level began to drop, and the exchange transfusion was aborted.
Barbara Haas, MD, PhD, and Lesley Gotlib Conn, PhD| May 1, 2017
Admitted to the ICU with septic shock, a man with a transplanted kidney developed hypotension and required new central venous access. Since providers anticipated using the patient's left internal jugular vein catheter for re-starting hemodialysis (making it unsuitable to use for resuscitation), the ICU team placed the central line in the right femoral vein. However, they failed to recognize that his transplanted kidney was on the right side, which meant that femoral catheter placement on that side was contraindicated.
Vineet Chopra, MD, MSc| February 1, 2016
Hospitalized with poorly controlled diabetes, a man had a peripherally inserted central catheter (PICC) placed for intravenous pain medications, intravenous fluids, and parenteral nutrition. The next day, the patient complained of headache, unilateral vision loss, and left-sided tingling and numbness. Misplacement of the PICC in a left-sided superior vena cava had led to embolic strokes.
Matthew S. Russell, MD, and Marika D. Russell, MD| August 21, 2015
Admitted to the hospital with sepsis and pneumonia, an elderly man developed acute respiratory distress syndrome requiring mechanical ventilation. On hospital day 12, clinicians placed a tracheostomy, and a few days later the patient developed acute hypoxia and ultimately went into cardiac arrest when his tracheostomy tube became dislodged.
Dustin W. Ballard, MD, MBE; David R. Vinson, MD; and Dustin G. Mark, MD| May 1, 2015
A man with a history of poorly controlled diabetes and pancreatic insufficiency was found unresponsive. Paramedics transported him to the emergency department, where a resident placed a right internal jugular line for access but was unable to confirm placement. The resident pulled the line, opened a second line insertion kit, started over, and confirmed placement with ultrasound. The patient went into cardiac arrest, and a chest radiograph noted a retained guidewire in the pulmonary artery.
Roy Ilan, MD, MSc| May 1, 2013
A woman was emergently admitted for surgery for acute appendicitis. Although the patient had a chest port for breast cancer chemotherapy, the surgeon demanded that a peripherally inserted central catheter (PICC) be placed. The patient developed blood clots from the PICC, and surgery was cancelled. Significant complications, including perforation, peritonitis, and prolonged hospitalization, arose from managing the appendicitis conservatively.
Mark Ault, MD, and Bradley Rosen, MD, MBA| February 1, 2013
A woman found unresponsive at home presented to the ED via ambulance. The cardiology team used the central line placed during resuscitation to deliver medications and fluids during pacemaker insertion. Hours later, a chest radiograph showed whiteout of the right lung, and clinicians realized that the tip of the line was actually within the lung.
Nancy Moureau, BSN, RN, CRNI, CPUI, VA-BC| December 1, 2012
A woman undergoing treatment for myasthenia gravis via PICC developed extensive catheter-related thrombosis, bacteremia, and sepsis, and ultimately died. Although the PICC line was placed at one facility, the patient was receiving treatment at another, raising questions about who had responsibility for the line.
Rita Redberg, MD, MSc| December 1, 2011
A patient with Guillain-Barré syndrome received more than the recommended number of plasmapheresis treatments. When the ordering physicians were asked why so many treatments were given, they both responded that the patient was improving so they felt that more treatments would help him recover even more.
Christopher R. Lee, MD| October 1, 2009
Following surgery for peripheral vascular disease, a patient otherwise ready for discharge complains of liquid shooting from his nose. The surgeons make the patient NPO and order a consultation from an otolaryngologist, who discovers the nasopharyngeal airway still lodged in the patient's nasal cavity.
Angela C. Joseph, RN, MSN, CURN| November 1, 2006
Following elective surgery, a man with benign prostatic hypertrophy began having trouble with urination. Delay in addressing this issue caused discomfort and the need for catheterization and antibiotics.
Jonathan S. Jahr, MD; Puya Hosseini| November 1, 2006
An elderly woman underwent knee replacement, during which her airway was maintained with a laryngeal mask airway. However, she developed a fever and fullness in her neck, which a CT scan revealed to be retropharyngeal and mediastinal abscesses.
D. John Doyle, MD, PhD | August 21, 2005
Following surgery, a woman receives morphine via a patient-controlled analgesia (PCA) pump. A few hours after arriving on the floor, she is found barely breathing.