WebM&M: Case Studies
WebM&M (Morbidity & Mortality Rounds on the Web) features expert analysis of medical errors reported anonymously by our readers. Spotlight Cases include interactive learning modules available for CME. Commentaries are written by patient safety experts and published monthly.
Have you encountered medical errors or patient safety issues? Submit your case below to help the medical community and to prevent similar errors in the future.
This Month's WebM&Ms
This case describes a man in his 70s with a history of multiple myeloma and multiple healthcare encounters for diarrhea in the previous five years, which had always been attributed to viral or unknown causes, without any microbiologic or serologic... Read More
A 63-year-old woman was admitted to a hospital for anterior cervical discectomy (levels C4-C7) and plating for cervical spinal stenosis under general anesthesia. The operation was uneventful and intraoperative neuromonitoring was used to help prevent... Read More
A 62-year-old Spanish-speaking woman presented to the pre-anesthesia area for elective removal of a left thigh lipoma. Expecting a relatively simple outpatient operation, the anesthesiologist opted not to use a Spanish language translator and... Read More
A 65-year-old man with metastatic liver disease presented to the hospital with worsening abdominal pain after a partial hepatectomy and development of a large ventral hernia. Imaging studies revealed perforated diverticulitis. A goals-of-care... Read More
All WebM&M: Case Studies (107)
A 52-year-old woman presented for a lumpectomy with lymphoscintigraphy and sentinel lymph node biopsy (SLNB) after being diagnosed with ductal carcinoma in situ (DICS). On the day of surgery, the patient was met in the pre-operative unit by several different providers (pre-operative nurse, resident physician, attending physician, and anethesiology team) to help prepare her for the procedure. In the OR, the surgical team performed two separate time-outs while the patient was being prepped, placed under general anesthesia, and draped. After the attending physician began operating, she realized that no radiotracer dye had been injected for the SNLB – a key process step that was supposed to have occurred prior to the surgery. The nuclear medicine team never saw the patient preoperatively, and none of the staff members or teams realized this until the patient was under general anesthesia with an open incision. The commentary discusses how pre-operative checklist protocols can help multidisciplinary teams avoid communication errors and reduce opportunities for adverse events.
A 32-year-old pregnant woman presented with prelabor rupture of membranes at 37 weeks’ gestation. During labor, the fetal heart rate dropped suddenly and the obstetric provider diagnosed umbilical cord prolapse and called for an emergency cesarean delivery. Uterine atony was noted after delivery of the placenta, which quickly responded to oxytocin bolus and uterine massage. After delivery, the patient was transferred to the post-anesthesia care unit (PACU) and monitored for 90 minutes, after which she was deemed stable, despite some abnormal vital signs. All monitor alarm functions were silenced to help the patient rest until a bed became available on the maternity floor. After another 90 minutes, the patient’s nurse discovered her unresponsive and the bedsheets were blood-soaked. A massive transfusion was ordered and uterotonic medications were administered, but vaginal bleeding continued. During an emergency laparotomy, the uterus was noted to be atonic despite uterotonic therapy, requiring an emergency hysterectomy. The commentary discusses the importance and use of early maternal warning systems, checklists and protocols to avoid poor maternal outcomes.
A 6-week-old infant underwent a craniotomy and excision of abnormal brain tissue for treatment of hemimegalencephaly and epilepsy. A right femoral central venous catheter and an arterial catheter were inserted, as well as 22-gauge intravenous catheter inserted into the external jugular vein, which was covered with surgical drapes. During the surgical procedure, the neurosurgeon adjusted the patient’s head, displacing the external jugular intravenous catheter into the subcutaneous tissue. The catheter’s dislodgment went unnoticed due to its position underneath the surgical drapes. The commentary discusses the importance intraoperative monitoring of intravenous catheters and the use of surgical safety checklists to improve communication and prevent surgical complications.
A seven-year-old girl with esophageal stenosis underwent upper endoscopy with esophageal dilation under general anesthesia. During the procedure, she was fully monitored with a continuous arterial oxygen saturation probe, heart rate monitors, two-lead electrocardiography, continuous capnography, and non-invasive arterial blood pressure measurements. The attending gastroenterologist and endoscopist were serially dilating the esophagus with larger and larger rigid dilators when the patient suddenly developed hypotension. She was immediately given a fluid bolus, phenylephrine, and 100% oxygen but still developed cardiac arrest. Cardiopulmonary resuscitation was initiated with cardiac massage, but she could not be resuscitated and died. This commentary highlights the role of communication between providers, necessary technical steps to mitigate the risks of upper endoscopy in children, and the importance of education and training for care team members.
A 61-year-old male was admitted for a right total knee replacement under regional anesthesia. The surgeon – unaware that the anesthesiologist had already performed a right femoral nerve block with 20 ml (100mg) of 0.5% racemic bupivacaine for postoperative analgesia – also infiltrated the arthroplasty wound with 200 mg of ropivacaine. The patient was sedated with an infusion of propofol throughout the procedure. At the end of the procedure, after stopping the propofol infusion, the patient remained unresponsive, and the anesthesiologist diagnosed the patient with Local Anesthetic Systemic Toxicity (LAST). The commentary addresses the symptoms of LAST, the importance of adhering to local anesthetic dosing guidelines, and the essential role of effective communication between operating room team members.
A 64-year-old woman was admitted to the hospital for aortic valve replacement and aortic aneurysm repair. Following surgery, she became hypotensive and was given intravenous fluid boluses and vasopressor support with norepinephrine. On postoperative day 2, a fluid bolus was ordered; however, the fluid bag was attached to the IV line that had the vasopressor at a Y-site and the bolus was initiated. The error was recognized after 15 minutes of infusion, but the patient had ongoing hypotension following the inadvertent bolus. The commentary summarizes the common errors associated with administration of multiple intravenous infusions in intensive care settings and gives recommendations for reducing errors associated with co-administration of infusions.
A 65-year-old man with a history of type 2 diabetes mellitus, hypertension, and coronary artery disease was transferred from a Level III trauma center to a Level I trauma center with lower extremity paralysis after a ground level fall complicated by a 9-cm abdominal aortic aneurysm and cervical spinal cord injury. Post transfer, the patient was noted to have rapidly progressive ascending paralysis. Magnetic resonance imaging (MRI) revealed severe spinal stenosis involving C3-4 and post-traumatic cord edema/contusion involving C6-7. A continuous intravenous (IV) infusion of norepinephrine was initiated to maintain adequate spinal cord perfusion, with a target mean arterial pressure goal of greater than 85 mmHg. Unfortunately, norepinephrine was incorrectly programmed into the infusion pump for a weight-based dose of 0.5 mcg/kg/min rather than the ordered dose of 0.5 mcg/min, resulting in a dose that was 70 times greater than intended. The patient experienced bradycardia and cardiac arrest and subsequently died.
A 60-year-old male presented to the emergency department (ED) with his partner after an episode of dizziness and syncope when exercising. An electrocardiogram demonstrated non-ST-elevation myocardial infarction abnormalities. A brain CT scan was ordered but the images were not assessed prior to initiation of anticoagulation treatment. While awaiting further testing, the patient’s heart rate slowed and a full-body CT scan demonstrated an intracranial hemorrhage. An emergent craniotomy was performed and the patient later died. The commentary discusses the influence of cognitive errors and the high-risk nature of anticoagulation contributing to this medical error, and the use of systematic interventions such as checklists and forcing functions to mitigate cognitive biases and prevent adverse outcomes.
A 58-year-old female receiving treatment for transformed lymphoma was admitted to the intensive care unit (ICU) with E. coli bacteremia and colitis secondary to neutropenia, and ongoing hiccups lasting more than 48 hours. She was prescribed thioridazine 10 mg twice daily for the hiccups and received four doses without resolution; the dose was then increased to 15 mg and again to 25 mg without resolution. When she was transferred back to the inpatient floor, the pharmacist, in reviewing her records and speaking with the resident physician, thioridazine (brand name Mellaril) had been prescribed when chlorpromazine (brand name Thorazine) had been intended. The commentary discusses the use of computerized physician order entry (CPOE) to reduce prescribing errors in inpatient settings and the importance of having a pharmacist on the patient care team to avoid prescribing errors involving less commonly prescribed medications.